HOME > Products > LOWTEM Smart 150D

LOWTEM Smart 150D

1. Rapid Warmup & Dry System
2. Convenient and Safe Sterilizing Agent
3. 7” full touch LCD, Easy Monitoring the Cycle Information
4. Plug and Play
5. USB History Memory
6. Automatic PM Alarm System
7. Built in Thermal Printer, Printout with Actual Cycle Information
8. Login Function
9. Monitoring System
10. Open/Close Foot Switch
11. Sliding Door
12. Double Door System

  • 1   Rapid Warmup & Dry System
    • 1.
    • The world’s first patented “Rapid Warmup and Dry System” allows to overcome the humidity-related problem.
    • 2.
    • LOWTEM Series automatically removes residual moisture through the enhanced drying performance for medical devices in warm up phase.
    • 3.
    • “Rapid Warmup and Dry System” gets rid of Cold Points and maintains same temperature inside chamber, which is very effective for sterilizing the complicated medical devices with its strong penetration power.
  • 2   Convenient and Safe Sterilizing Agent
    • 1.
    • “Tank type” sterilant is safe for users to store, to deliver, and to use.
    • 2.
    • The automatic system for changing and installing sterilant tank is convenient and safe for users.
    • 3.
    • LOWTEM Series’ tank type sterilant does not need to be replaced often, as it can be used scores of times.
  • 3   7” full touch LCD, Easy Monitoring the Cycle Information
    • 1.
    • LOWTEM Series’ 7”full touch LCD monitor provides with all functions of the machine using simple letters, pictures, and icons.
    • 2.
    • 2. User can monitor the actual temperature and pressure from the graph on the monitor.
  • 4   Plug and Play
  • LOWTEM Series’ warming up time is very rapid (Maximum 15 min) after main power is on, so that standby power consumption is zero during off-duty or overnight.
  • 5   USB History Memory
  • LOWTEM Series’ sterilization history can be downloaded to your USB memory stick, and maintained at your convenience. Furthermore, it can be remote-controlled by its own out-of-state network system.
  • 6   Automatic PM Alarm System
  • LOWTEM Series provide alarms to prevent from irregular maintenance.
    Automatic PM Alarm System is very useful for users and engineers to be noticed.
  • 7   Built in Thermal Printer, Printout with Actual Cycle Information
  • Built-in thermal printer uses 60mm (Ø) Roll paper. Users do not need to replace it often.
    The printout from this printer provides temperature, pressure with the cycle graph on the paper.
  • 8   Login Function
  • LOWTEM Series provide User ID and PW, so that hospital can manage users who access the sterilizer.
  • 9   Monitoring System
    • 1.
    • Cycle temperature, pressure, and sterilization cycle status can be remotely monitored.
    • 2.
    • Thanks to the monitoring system, LOWTEM Series can be maintained and upgraded easily.
  • 10   Open/Close Foot Switch
  • LOWTEM Smart 150/150D has hands-free door operating system. With Foot Switch, user can easily open and close the chamber door.
  • 11   Double Door System
  • LOWTEM Smart 150D has an optimizing pass-through double door system for CSSD, satisfying a need for separation of clean and sterile zone.
  • 12   Sliding Door
    • 1.
    • LOWTEM Smart 150/150D adopts hands-free sliding door operating system. User can easily load the items.
    • 2.
    • This sliding door adopts a dual structure of safety.
    • 3.
    • User can easily open this sliding door using LCD touch, and Foot Sensor.
Specifications
Item Description
Sterilizing Agent Hydrogen Peroxide
15 Cycles / Bottle
Total Cycle Time Quick 40+5 Min
Standard 50+5 Min
Special 60+5 Min
Cycle Temperature 50±5℃
SAL (Sterility Assurance Level) 10-6
By-Products Oxygen And Vapor Water Only
Lumen Claims Rigid Lumen & Flexible Lumen, Endoscopes
Chamber Type Rectangular, Double Door System
Material Stainless Steel(SUS)
Dimensions Overall 700mm(W) x 1640mm(H) x 980mm(D)
Chamber 450mm(W) x 450mm(H) x 760mm(D)
Volume Total : 150 Liter
Weight 350kg
Control Microprocessor & Windows CE Embedded
Cycle Information Screen, Printer, USB, 100/10Mbps Ethernet(Option)
PM Cycle Automatic Alarm & Setup
Electrical 110V/220V, 50/60Hz, 1 Phase, 3000W
Installation Requirements Front, Rear : 100cm
Left Side, Right Side: 10cm
Placement : Built-in Wheels Provide Mobility
Room Conditions 5 ~ 40℃, 0 ~ 95%RH(Non-Condensing)
Printer Built-in Thermal Printer(60Ø Roll Paper)
Cycle Parameters (Temp, Pressure, Time, Daily&Total Cycle, Etc)
Alarm & Error Display
Others Emergency Stop(Front), Operator ID Login, Self-Diagnosis,
Multi-Language, RFID Coding System

※ The descriptions and pictures in this publication can be changed without previous notice to improve products.